<?xml version='1.0' encoding='UTF-8'?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1d1 20130915//EN" "JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink">
  <front>
    <journal-meta id="journal-meta-c5b32a6e5da94497b420c3635e42ec2b">
      <journal-id journal-id-type="nlm-ta">Prathima Institute of Medical Sciences</journal-id>
      <journal-id journal-id-type="publisher-id">Prathima Institute of Medical Sciences</journal-id>
      <journal-id journal-id-type="journal_submission_guidelines">https://www.pimr.org.in/instructions.php</journal-id>
      <journal-title-group>
        <journal-title>Perspectives in Medical Research</journal-title>
      </journal-title-group>
      <issn publication-format="electronic">2348-229X</issn>
      <issn publication-format="print">2348-1447</issn>
    </journal-meta>
    <article-meta id="article-meta-35bb8cf84c1447ddb4118fc4893e24d7">
      <article-id pub-id-type="doi">10.47799/pimr.1302.25.46</article-id>
      <article-categories>
        <subj-group>
          <subject>Case Report</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title id="article-title-04f84a55a39048c4950eed46e8d2e7fc">Broken Kirschner Wire Elbow- Removed Successfully by Cannulated Drilling Technique</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name id="name-810ebb58f01f46c991d5a0ea98deb3b7">
            <surname>Bhajipale</surname>
            <given-names>Sanjay Ramchandra</given-names>
          </name>
          <email>rushtosanjay@yahoo.co.in</email>
          <xref id="xref-34a7f912843240538da6cf7a6fa1dfa3" rid="aff-265d2d922ead4e19a86aa05a29f1b617" ref-type="aff">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name id="name-1fd5f425dfbd42cfa917f2208d3beac7">
            <surname>Mothilal</surname>
            <given-names>J</given-names>
          </name>
          <xref id="xref-5092600dc539418ea28d9def0b7c21a5" rid="aff-ea9f3bbfce7241e68a2e78d7ec832fbe" ref-type="aff">2</xref>
        </contrib>
        <contrib contrib-type="author">
          <name id="name-54491126f4c44505bf3aed4e3bf8643c">
            <surname>Nandurkar</surname>
            <given-names>Shraddha</given-names>
          </name>
          <xref id="xref-e9b5249a4d9d41deb5d9d4c2da59e45d" rid="aff-0d6f397392aa4cc2b685274551269aec" ref-type="aff">3</xref>
        </contrib>
        <aff id="aff-265d2d922ead4e19a86aa05a29f1b617">
          <institution>Consultant Orthopaedic, Trauma &amp; Joint Replacement Surgeon, Reliable Multispeciality Hospital and Research Center</institution>
          <addr-line>Nagpur , Maharashtra, 440024</addr-line>
          <country country="IN">India</country>
        </aff>
        <aff id="aff-ea9f3bbfce7241e68a2e78d7ec832fbe">
          <institution>Professor, Department of Orthopaedic Surgery, Pratima Institute of Medical Sciences</institution>
          <addr-line>Nagunur, Karimnagar, Telangana, 505415</addr-line>
          <country country="IN">India</country>
        </aff>
        <aff id="aff-0d6f397392aa4cc2b685274551269aec">
          <institution>Senior Resident, Reliable Multispeciality Hospital and Research Center</institution>
          <addr-line>Nagpur , Maharashtra, 440024</addr-line>
          <country country="IN">India</country>
        </aff>
      </contrib-group>
      <pub-date date-type="pub">
        <day>11</day>
        <month>9</month>
        <year>2025</year>
      </pub-date>
      <volume>13</volume>
      <issue>2</issue>
      <fpage>134</fpage>
      <history>
        <date date-type="received">
          <day>21</day>
          <month>7</month>
          <year>2025</year>
        </date>
        <date date-type="accepted">
          <day>21</day>
          <month>8</month>
          <year>2025</year>
        </date>
        <date date-type="rev-recd">
          <day>12</day>
          <month>8</month>
          <year>2025</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>©2025 (Bhajipale) et al. This is an open-access journal, and articles are distributed under the terms of the Creative Commons Attribution License CC-BY 4.0. (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are credited.</copyright-statement>
        <copyright-year>2025</copyright-year>
      </permissions>
      <abstract id="abstract-abstract-title-ace4be9c50a54b3e9cb9bd2870d233aa">
        <title id="abstract-title-ace4be9c50a54b3e9cb9bd2870d233aa">Abstract</title>
        <p id="paragraph-ac244c5075a6419c92c20c30b2271da7">Kirschner wires (K-wires) are widely used in orthopaedic surgery as they are readily available, reliable, and cost-effective. Kirschner wires (K-wires) are used for old unreduced elbow dislocations, inserted through the olecranon and into the humerus, if the joint re-dislocates easily. K-wire breakage during removal is rare. 11 yrs male having 4 month old unreduced elbow dislocation was treated with open reduction and ulnohumeral K wire &amp; above elbow slab was applied. After 2 weeks K-wire broke during removal in outpatient department with the proximal piece completely retained in distal humerus intraarticularly. Elbow flexion &amp; extension was restricted. The Broken K wire was removed in operation theatre with patient under anaesthesia. In our case, there was no obvious cause of breakage, and the patient denied postoperative trauma. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.</p>
      </abstract>
      <kwd-group id="kwd-group-4c1f8d71a886476faa571d7f1823b045">
        <title>Keywords</title>
        <kwd>K wire</kwd>
        <kwd>Broken K wire</kwd>
        <kwd>Intraarticular</kwd>
        <kwd>Neglected elbow dislocation</kwd>
        <kwd>Cannulated drilling technique</kwd>
      </kwd-group>
      <funding-group>
        <funding-statement>None</funding-statement>
      </funding-group>
    </article-meta>
  </front>
  <body>
    <sec>
      <title id="title-039b584921b0494d882174fd034fa786">INTRODUCTION</title>
      <p id="paragraph-709b12eacc12413ca16c1f9a571b1dd7">Kirschner wires (K-wires) are widely used for fixation of fractures and if required in dislocations as they are readily available, reliable, and cost-effective <sup id="superscript-b1d5621bf509480c9cb5c08897d3e02b"><xref id="xref-a9dafa0409f84548bac58d2289bce26b" rid="R278596533805705" ref-type="bibr">1</xref></sup>. K wire breakage during removal is rare with one reported case in the literature <sup id="superscript-4927c52c673344ea8883b41589c4e9fa"><xref id="xref-cb394e97381f42afb8b5133e4baee3f1" rid="R278596533805701" ref-type="bibr">2</xref></sup>. We present a case of broken K-wire, which required retrieval due to intraarticular &amp; restriction of Elbow flexion &amp; extension. A 11-year male having old unreduced elbow dislocation was treated with open reduction and ulnohumeral K wire &amp; above elbow slab was applied. Two weeks postoperatively, patient came for K wire removal in outpatient department, during the removal, the K wire broke. Broken K wire was removed in operation theatre under Anaesthesia. A review of the literature demonstrates that K-wire complications occur relatively infrequently but being aware of possible management options should be known to operating surgeon.</p>
    </sec>
    <sec>
      <title id="t-88aed870e90f">
        <bold id="strong-52858ef6d3d445249786e471dec98cb3">CASE PRESENTATION</bold>
      </title>
      <p id="paragraph-fefcf687c74d412aa4602bbf6a0b2420">A 11-year-old school going male had fall while playing and sustained injury to left elbow, which was treated by bonesetter. Patient came to OPD for persistant swelling &amp; inability to lift weight, 4 month after injury. X-ray showed a displaced posterolateral dislocation of elbow (<xref id="x-de5d1ccfbf31" rid="figure-0a1ee3c45b394c479899cc9e48b10d4e" ref-type="fig">Figure 1</xref> <bold id="strong-3e72394ef0de421caf1478df40395f5d">(a) and (b)</bold>). This elbow dislocation was treated with open reduction and ulnohumeral K wire &amp; above elbow slab was applied (<xref id="x-6cc360e0ef2b" rid="figure-0a1ee3c45b394c479899cc9e48b10d4e" ref-type="fig">Figure 1</xref> <bold id="strong-01b6c872c59a486f9f8e2013d8160249">(c) and (d)</bold>). Two weeks postoperatively, patient came for K wire removal in outpatient department, during the removal, the K wire broke. Due to restriction of flexion &amp; extension, the retained K-wire being intrarticular required removal. The patient was taken to operating theatre and general anaesthesia was given.</p>
      <p id="paragraph-d77a3269124c4647ad0074149b47b16d">Entry of broken K wire was assessed with similar new K wire (<xref id="x-6c7c8b0215ff" rid="figure-9d87caf8c8484d93a5558ecfb77f9d29" ref-type="fig">Figure 2</xref> <bold id="strong-1024f1c9fcd74d64ae7a2043f81a98b8">(a)</bold><bold id="strong-5bc7d478f80d4f6592ddf03058cfb7e7"> </bold><bold id="strong-38f9d1803d5c4475995008084a6af019">and</bold><bold id="strong-ccf1db93a2f24c90b3ba64ecba969928"> </bold><bold id="strong-07778d9b7161416f96aed230091957b5">(b)</bold>). Cannulated drill of 3.2 mm (<xref id="x-353bfa76720e" rid="figure-9d87caf8c8484d93a5558ecfb77f9d29" ref-type="fig">Figure 2</xref> <bold id="strong-0853dd3cee1d4bd1a73b4b9d397d9c13">(c))</bold> (after checking cannulation from piece of broken K wire). Cannulated drilling done in olecranon through same track (<xref id="x-8287b4e75bbb" rid="figure-9d87caf8c8484d93a5558ecfb77f9d29" ref-type="fig">Figure 2</xref> <bold id="strong-4e4a6e3b0f5849f691b2d1f1693f2dda">(d))</bold>. Cannulated drill was engaged in distal end of broken K wire (<xref id="x-d56568939a98" rid="figure-fdaf49f518e645018a41798f38452fe2" ref-type="fig">Figure 3</xref><bold id="strong-12e85a9d55f74cf3892cebbff6a3e9dd"> (a)</bold>). Cannulated drill was advanced further till most of broken K wire was engaged (<xref id="x-0171954e6220" rid="figure-fdaf49f518e645018a41798f38452fe2" ref-type="fig">Figure 3</xref><bold id="strong-83e7065afaa74ac69a6e2f10540007f5"> (b)</bold>). Retrograde and reverse drilling was done, which was suggestive of broken K wire being withdrawn back with cannulated drill (<xref id="x-a67d87a7e3f8" rid="figure-5f81f555ec01420fa4831ae608a8cbf4" ref-type="fig">Figure 4</xref> <bold id="strong-12b3db3735c247f3bf4fd82096e4b564">(a)</bold>). Cannulated drill was withdrawn fully with broken K wire inside. Elbow range of movements flexion, extension was full and broken K wire was removed (<xref id="x-6f1966e3bef8" rid="figure-5f81f555ec01420fa4831ae608a8cbf4" ref-type="fig">Figure 4</xref> <bold id="strong-9336c82c00a943bb83310f12b24b65aa">(b, c)</bold>).</p>
      <fig id="figure-0a1ee3c45b394c479899cc9e48b10d4e" orientation="portrait" fig-type="graphic" position="anchor">
        <label>Figure 1 </label>
        <caption id="caption-97739a66373b454d820d84d13f7edd48">
          <title id="title-44cc4d7a045b426eb233027bef0ccadf">
            <bold id="strong-25cb438d8a7b43c68428c322a93affe6"/>
            <bold id="strong-24334dfd9ab74e0faad9160b62e2c399">X-ray showing posterolateral dislocation of left elbow</bold>
            <bold id="strong-847fdb8974fa4100ad914195c74d8f67"> </bold>
            <bold id="strong-5a83e069e1b14b6aba59fba9184be569">(a,b),</bold>
            <bold id="strong-70325cf3d16c44eda600747ca8e28931"> which was treated with open reduction &amp; </bold>
            <bold id="strong-2ba80d311dbb4c31913eb5d13dd18b4d">ulnohumeral</bold>
            <bold id="strong-b6fbd45be38642f2b99778628a86a35c"> </bold>
            <bold id="strong-774146fce8674d71bede36f977b25db0">K wire fixation</bold>
            <bold id="strong-f7febbee4ee34af3b9b913bffca4c56c"> </bold>
            <bold id="strong-7fb8a493f9614bbdb2e9fe2a51d3ac71">(c,d)</bold>
          </title>
        </caption>
        <graphic id="graphic-e53a83cdd71549d091c762b00ef07d35" xlink:href="https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/5b392037-dc2d-454f-bd4a-f9d4da400d0eimage1.png"/>
      </fig>
      <fig id="figure-9d87caf8c8484d93a5558ecfb77f9d29" orientation="portrait" fig-type="graphic" position="anchor">
        <label>Figure 2 </label>
        <caption id="caption-306144e3a53c4c09a8d5ff8e8f8d4f53">
          <title id="title-b09a6bd80abc45b18e120a9618b021de">
            <bold id="strong-200842a0260f48198c5f10b88245ac7d"/>
            <bold id="strong-79bd208fa30949c6b95a42f758ca936a">(a)</bold>
            <bold id="strong-95ac34b82dd44c5e9dedde7e22cc20b1"> </bold>
            <bold id="strong-35eace9578804ed99cf76d5a2c5a9301">Radiographic view showing intraarticular broken K wire. (b) S</bold>
            <bold id="strong-15a4818496cf4ae9810f5ea0a959e75b">imilar </bold>
            <bold id="strong-3565d1423809487cb0f88128a2f7392c">K wire inserted in same track through ulna olecranon process. (c) 3.2 mm cannulated drill bit.</bold>
            <bold id="strong-d2a1e7c46d5b494f8a5d6dfbec114a94"> (d) </bold>
            <bold id="strong-17dc601f9d724220840bd7c75de3cdb5">Advanced through olecranon</bold>
          </title>
        </caption>
        <graphic id="graphic-862cc5aa6331406e82a788b230aeefb3" xlink:href="https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/5b392037-dc2d-454f-bd4a-f9d4da400d0eimage2.png"/>
      </fig>
      <fig id="figure-fdaf49f518e645018a41798f38452fe2" orientation="portrait" fig-type="graphic" position="anchor">
        <label>Figure 3 </label>
        <caption id="caption-9d2461f6146b4e119c30fd6878b3b2ad">
          <title id="title-b5ecbfb206734aa798249695b7789791">
            <bold id="strong-e55ed32da98d4fb099f83e94fcb17723"/>
            <bold id="strong-eb1a48f7452147a88dcbb473b3b85f00">(a) Radiographic view showing, cannulated</bold>
            <bold id="strong-b6e1420ebd554b978301026f63a3febe"> </bold>
            <bold id="strong-70474f3efc14484089acb82edf0f6542">drill engaged in distal end of broken K wire. (b) C</bold>
            <bold id="strong-b48dae5512654432b1c1a4f44b469fdb">annulated </bold>
            <bold id="strong-2284bc61197d4031a80c8648e3fa9f80">drill advanced further till most of broken K wire engaged</bold>
          </title>
        </caption>
        <graphic id="graphic-0618e253e01b4bf7aba68cf94d22c978" xlink:href="https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/5b392037-dc2d-454f-bd4a-f9d4da400d0eimage3.png"/>
      </fig>
      <fig id="figure-5f81f555ec01420fa4831ae608a8cbf4" orientation="portrait" fig-type="graphic" position="anchor">
        <label>Figure 4 </label>
        <caption id="caption-b5e8485a0ff64a6e86672134fdab7d58">
          <title id="title-2df42d2e85c14fa0b71b0c920e6b3d84">
            <bold id="strong-aad7aba2165b4261ac183ad1ebaf769c"/>
            <bold id="strong-bba27017275a465cacbef3c924434f55">(a) Radiographic view showing broken K wire being withdrawn back with cannulated drill.</bold>
            <bold id="strong-c350c55e28744d459d78f098abf81478"> </bold>
            <bold id="strong-de9887f05b04430db61e3cac9f4a7648">(b,c) Elbow after removal of broken K wire</bold>
          </title>
        </caption>
        <graphic id="graphic-6ab320625fb14f62aacab89be5ed53f6" xlink:href="https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/5b392037-dc2d-454f-bd4a-f9d4da400d0eimage4.png"/>
      </fig>
    </sec>
    <sec>
      <title id="title-d8a1e54f662c43d488b9d43c7e5bc532">DISCUSSION</title>
      <p id="paragraph-7873966c7d344aed84a7fda2dce29708">K-wire fixation is recommended in old unreduced elbow dislocations, if the joint re-dislocates easily, insertion of Kirschner wire through the olecranon and into the humerus is recommended. It is therefore not surprising that K-wire breakage is rare. In a prospective review of 11,856 orthopaedic procedures to determine the frequency of intraoperative instrument breakage, Pichler et al. reported K-wire breakage in only 14 cases (0.1%) <sup id="superscript-4a77cbcec5a8418db3f1a6fe28dbe5f1"><xref id="xref-44553459080c4d07ae843e9a29026df4" rid="R278596533805700" ref-type="bibr">3</xref></sup>. Literature it is documented complications have been reported in up to 18% of such cases including infection, pin loosening, loss of reduction, and pin migration <sup id="superscript-26cb4af94dfe445c84e8f1500aa2f3aa"><xref rid="R278596533805705" ref-type="bibr">1</xref>, <xref rid="R278596533805704" ref-type="bibr">4</xref></sup>. K-wire breakage during removal is rare with one reported case in the literature <sup id="superscript-aa8b93141229453ba90b9dd56e4a82f5"><xref id="xref-9187d7ab0b294a2cb30eb3ffdaab7cd5" rid="R278596533805701" ref-type="bibr">2</xref></sup>. Broken K wire in joint may lead to catastrophic sequelae in short to long term time, like injury to adjacent neurovascular bundles, restriction of joint movements, stiffness, migration of K wire <sup id="superscript-96d3c0b2eb1f406cb41f72f4e9277a19"><xref rid="R278596533805703" ref-type="bibr">5</xref>, <xref rid="R278596533805706" ref-type="bibr">6</xref></sup>. In our case, we have come to conclusion that possibly K wire can break due to young and active child even though supported by plaster it is difficult to have total immobility in elbow, that may cause repetitive stress on wire leading to metal fatigue <sup id="superscript-b2710912034f4bca9ad05ae9790e687d"><xref id="xref-e965f095492640369265fb58d095d404" rid="R278596533805702" ref-type="bibr">7</xref></sup>. Other possible cause of breakage could be smaller diameter of K wire leading to early fatigue. We believe that even though patient denied postoperative trauma or attempts to mobilise elbow joint, but we cannot relay totally on it. Treating surgeon should not underestimate this rare &amp; uncommon complication which requires removal to avoid untoward and dreaded complications <sup id="superscript-7cdd94c675c14117a5de8ceaac6cfec3"><xref rid="R278596533805703" ref-type="bibr">5</xref>, <xref rid="R278596533805706" ref-type="bibr">6</xref>, <xref rid="R278596533805702" ref-type="bibr">7</xref></sup>. Removal of intraarticular K wire requires meticulous planning and execution. We found cannulated drilling technique to be useful. Large diameter K wires can minimise risk of breakage <sup id="superscript-d80dacb8b02a4602ab8e1016fb5d7fa5"><xref id="xref-ee9a2e6e782345fcaf9c0b84020400da" rid="R278596533805702" ref-type="bibr">7</xref></sup>. Literature supports that as purpose of K wire is served, for which it was inserted then it should be removed to avoid potential complications <sup id="superscript-d98482518ec94230b9a7c664a82975b8"><xref id="xref-79f19d00a7f94a3b8b8265a91b77949f" rid="R278596533805707" ref-type="bibr">8</xref></sup>.</p>
    </sec>
    <sec>
      <title id="title-f68e32c7560c4bce8e40b4bf84d9043f">CONCLUSION</title>
      <p id="paragraph-ee60c78d795e4b25a58e89e44d644c58">K wire may break even though it is inserted for short time stability/ stabilization of joints. Once breakage is confirmed it should be removed to avoid future catastrophic sequelae of retained broken implant. Cannulated drilling technique is useful technique for removal of broken, retained K wire. However, arthrotomy of joint may be required if technique is not successful.</p>
    </sec>
    <sec>
      <title id="t-fd7cb2a75e64">Disclosure</title>
      <p id="p-59c27ab87c0c"><bold id="s-a14de70c3ca6">Competing interests: </bold>The author(s) declare that they have no competing interests.</p>
      <p id="p-eaab96c36088"><bold id="s-c73d474131eb">Consent: </bold>Patient has given their informed consent for the case report to be published.</p>
      <p id="p-024e1235b325"><bold id="s-df87bbd79c04">Funding: </bold>None</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R278596533805705">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Stahl</surname>
              <given-names>S</given-names>
            </name>
            <name>
              <surname>Schwartz</surname>
              <given-names>O</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>Complications of K-wire fixation of fractures and dislocations in the hand and wrist</article-title>
          <source>Archives of Orthopaedic and Trauma Surgery</source>
          <year>2001</year>
          <volume>121</volume>
          <issue>9</issue>
          <fpage>527</fpage>
          <lpage>530</lpage>
          <issn>0936-8051, 1434-3916</issn>
          <publisher-name>Springer Science and Business Media LLC</publisher-name>
          <uri>https://dx.doi.org/10.1007/s004020100279</uri>
        </element-citation>
      </ref>
      <ref id="R278596533805701">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Kirschner</surname>
              <given-names>M</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>Zur behandlung der knochenbrüche</article-title>
          <source>Arch Klein Chir</source>
          <year>1931</year>
          <volume>167</volume>
          <fpage>1</fpage>
          <lpage>2</lpage>
        </element-citation>
      </ref>
      <ref id="R278596533805700">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Pichler</surname>
              <given-names>Wolfgang</given-names>
            </name>
            <name>
              <surname>Mazzurana</surname>
              <given-names>Peter</given-names>
            </name>
            <name>
              <surname>Clement</surname>
              <given-names>Hans</given-names>
            </name>
            <name>
              <surname>Grechenig</surname>
              <given-names>Stephan</given-names>
            </name>
            <name>
              <surname>Mauschitz</surname>
              <given-names>Renate</given-names>
            </name>
            <name>
              <surname>Grechenig</surname>
              <given-names>Wolfgang</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>Frequency of Instrument Breakage During Orthopaedic Procedures and Its Effects on Patients</article-title>
          <source>The Journal of Bone and Joint Surgery-American Volume</source>
          <year>2008</year>
          <volume>90</volume>
          <issue>12</issue>
          <fpage>2652</fpage>
          <lpage>2654</lpage>
          <issn>0021-9355</issn>
          <publisher-name>Ovid Technologies (Wolters Kluwer Health)</publisher-name>
          <uri>https://dx.doi.org/10.2106/jbjs.h.00163</uri>
        </element-citation>
      </ref>
      <ref id="R278596533805704">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Hong</surname>
              <given-names>Seong Jae</given-names>
            </name>
            <name>
              <surname>Lee</surname>
              <given-names>Hyun Jic</given-names>
            </name>
            <name>
              <surname>Kim</surname>
              <given-names>Jin Young</given-names>
            </name>
            <name>
              <surname>Eo</surname>
              <given-names>Su Rak</given-names>
            </name>
            <name>
              <surname>Cho</surname>
              <given-names>Sang Hun</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>K-Wire Breakage During Metalware Removal Due to a Defective K-Wire Shaft</article-title>
          <source>Archives of Plastic Surgery</source>
          <year>2013</year>
          <volume>40</volume>
          <issue>05</issue>
          <fpage>655</fpage>
          <lpage>657</lpage>
          <issn>2234-6163, 2234-6171</issn>
          <publisher-name>Georg Thieme Verlag KG</publisher-name>
          <uri>https://dx.doi.org/10.5999/aps.2013.40.5.655</uri>
        </element-citation>
      </ref>
      <ref id="R278596533805703">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Chen</surname>
              <given-names>Y J</given-names>
            </name>
            <name>
              <surname>Wu</surname>
              <given-names>C C</given-names>
            </name>
            <name>
              <surname>Hsu</surname>
              <given-names>R W</given-names>
            </name>
            <name>
              <surname>Shih</surname>
              <given-names>C H</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>The intra-articular migration of the broken wire: A rare complication of circumferential wiring in patellar fractures </article-title>
          <source>Changgeng Yi Xue Za Zhi</source>
          <year>1994</year>
          <volume>17</volume>
          <fpage>276</fpage>
          <lpage>279</lpage>
          <uri>https://pubmed.ncbi.nlm.nih.gov/7954008/</uri>
        </element-citation>
      </ref>
      <ref id="R278596533805706">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Choi</surname>
              <given-names>Ho-Rim</given-names>
            </name>
            <name>
              <surname>Min</surname>
              <given-names>Kyung-Dae</given-names>
            </name>
            <name>
              <surname>Choi</surname>
              <given-names>Sang-Wook</given-names>
            </name>
            <name>
              <surname>Lee</surname>
              <given-names>Byung-Ill</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>Migration to the popliteal fossa of broken wires from a fixed patellar fracture</article-title>
          <source>The Knee</source>
          <year>2008</year>
          <volume>15</volume>
          <issue>6</issue>
          <fpage>491</fpage>
          <lpage>493</lpage>
          <issn>0968-0160</issn>
          <publisher-name>Elsevier BV</publisher-name>
          <uri>https://dx.doi.org/10.1016/j.knee.2008.06.005</uri>
        </element-citation>
      </ref>
      <ref id="R278596533805702">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Biddau</surname>
              <given-names>F</given-names>
            </name>
            <name>
              <surname>Fioriti</surname>
              <given-names>M</given-names>
            </name>
            <name>
              <surname>Benelli</surname>
              <given-names>G</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>Migration of a Broken Cerclage Wire from the Patella into the Heart: A Case Report</article-title>
          <source>JBJS Case Connector</source>
          <year>2006</year>
          <volume>88</volume>
          <fpage>2057</fpage>
          <lpage>2059</lpage>
          <issn>2160-3251</issn>
          <publisher-name>Ovid Technologies (Wolters Kluwer Health)</publisher-name>
          <uri>https://dx.doi.org/10.2106/jbjs.e.00968</uri>
        </element-citation>
      </ref>
      <ref id="R278596533805707">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Mak</surname>
              <given-names>Nin-Tai Sammy</given-names>
            </name>
            <collab/>
          </person-group>
          <article-title>Breakage and migration of metal wires in operated patella fractures: Does it correlate with time</article-title>
          <source>Journal of Orthopaedics, Trauma and Rehabilitation</source>
          <year>2013</year>
          <volume>17</volume>
          <issue>1</issue>
          <fpage>13</fpage>
          <lpage>16</lpage>
          <uri>https://doi.org/10.1016/j.jotr.2012.04.003</uri>
        </element-citation>
      </ref>
    </ref-list>
  </back>
</article>
